LX 450 L6-4.5L (1FZ-FE) (1996)
1-4-1-2:
Closed with the ignition SW at ON position or key off operated
M 4 MOON ROOF CONTROL RELAY
11-Ground: Always continuity
6-Ground: Approx. 12 Volts with the ignition SW at ON position or key off operated
4-Ground: Approx. 12 Volts with the ignition SW ON and the moon roof control SW at CLOSE or UP position
(except approx. 100 mm (3.941 in.) 2 seconds in the before CLOSED position)
5-Ground: Approx. 12 Volts with the ignition SW ON and the moon roof control SW at OPEN or DOWN position
9-Ground: Approx. 12 Volts --> 0 Volts with from open to close
0 Volts with UP or DOWN position
0 Volts --> approx. 12 Volts with approx. 100 mm (3.941 in.) 2 seconds in the before CLOSED position
8-Ground: 0 Volts --> approx. 12 Volts with from UP to DOWN position
N 5 MOON ROOF CONTROL SW
5-4:
Closed with the moon roof control SW at UP position
6-4:
Closed with the moon roof control SW at CLOSE position
2-4:
Closed with the moon roof control SW at DOWN position
3-4:
Closed with the moon roof control SW at OPEN position
4-Ground: Always continuity
Connector Joining Wire Harness and Wire Harness
Connector Joining Wire Harness And Wire Harness
Location Of Connector Joining Wire Harness And Wire Harness (Fig 32)