LX 450 L6-4.5L (1FZ-FE) (1996)
Position Of Parts In Instrument Panel (2 Of 2) (Fig 25)
Service Hints
C 6 CIGARETTE LIGHTER
2-Ground: Approx. 12 Volts with the Ignition SW at ACC or ON position
1-Ground: Always Continuity
C 9 CLOCK
3-Ground: Always Approx. 12 Volts (Power For Clock)
4-Ground: Approx. 12 Volts with the Ignition SW at ACC or ON position (Power For Indication)
2-Ground: Approx. 12 Volts with the Light Control SW at TAIL or HEAD position
1-Ground: Always Continuity