Component Tests and General Diagnostics|Page 2633 > < Component Tests and General Diagnostics
Page 2
background image

-

Using an ohmmeter, measure the resistance between the terminals (B1 - S1 and S3, B2 - S2 and S4).

Resistance:
Cold:15-25 Ohms
Hot: 20-30 Ohms
 

-

If resistance is not as specified, replace the IAC valve.

-

Reconnect the IAC valve connector.