lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

A/C - Sensor Inspection Procedures|Page 161 > < A/C - Sensor Inspection Procedures|Page 159
Page 9
background image

a.

Turn the ignition switch ON.

b.

Using the tester, measure the voltage between terminals TSD (+) and CLTE (-) of the connector under the following conditions:

^

Cover the sensor with a cloth to avoid direct light.

^

Expose the sensor to light from a distance of 300 mm (11.81 in.) or less with an inspection light.

HINT:

^

If the light is weak, the sensor may not react. Be sure to use an incandescent light for an inspection light.

^

Do not disconnect the solar sensor connector.

Standard:

6.

Inspect Room Humidity Sensor.

Measure the humidity and output voltage of the humidity sensor when the sensor is installed on the vehicle and the temperature at the humidity
sensor position (room temperature sensor position) is 77°F (25°C). If the output voltage is within the specifications according to the graph and
table below, the sensor is normal.

HINT:

For the inspection procedure of the room temperature sensor, refer to "Room Temperature Sensor Inspection Procedure" in this bulletin.

A.

Turn the ignition switch to the ON position.

B.

Measure the voltage between terminal VO (3) and GND (2) of the room humidity sensor.

A/C - Sensor Inspection Procedures|Page 161 > < A/C - Sensor Inspection Procedures|Page 159