Condenser Fan: Testing and Inspection

1. INSPECT CONDENSER FAN OPERATION

Inspect the fan operation in these conditions, as shown in the chart below.
Test conditions:
-

Start engine

-

Blower speed control switch position "HI"

-

Temperature control dial at "COOL" position

-

Set manifold gauge set

-

A/C switch ON

If operation is not as specified, proceed to the next inspection

2. INSPECT CONDENSER FAN MOTOR OPERATION

a. Disconnect the fan connector.
b. Connect battery and ammeter to the fan connector, as shown in the illustration.
c. Check that the fan rotates smoothly and check the reading on the ammeter.

Specified amperage: 9.8 ± 1.5 A at 20° C (68° F)
-

If operation is not as specified, replace the fan motor.

-

If operation is as specified, check the pressure switch, cooling fan relays and water temp. switch.