RX 300 FWD V6-3.0L (1MZ-FE) (1999)
Auxiliary Power Outlet: Electrical Diagrams
Service Hints
F11 FRONT POWER OUTLET
2-GROUND: Approx. 12 Volts with the ignition SW at ACC or ON position
1-GROUND: Always continuity
R18 REAR POWER OUTLET
2-GROUND: Approx. 12 Volts with the ignition SW at ACC or ON position
1-GROUND: Always continuity