lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Engine Controls - O2 Sensor Monitor Threshold Values|Page 3001 > < Engine Controls - MIL ON/O2 Sensor DTC's Stored|Page 2996
Page 1
background image

Oxygen Sensor: All Technical Service Bulletins
Engine Controls - O2 Sensor Monitor Threshold Values

SPECIAL SERVICE TOOLS
SS002-03

December 17, 2003

Title
O2S TEST RESULTS (MODE 05)

Models
All '96 - '03 & '04 RX 330

Introduction

This Service Bulletin contains Oxygen Sensor (O2S) Monitor threshold values for all models from 1996 to 2003 and some 2004 models. Starting in
2004, the O2S Monitor threshold values can be found in the repair manual. These values are used when analyzing the 02S test results to determine the
O2S condition.

Applicable Vehicles
^

All 1996 - 2003 model year Lexus vehicles.

^

2004 model year RX 330 vehicles.

Function Description

Checking O2S Test Results

To view O2S test results, the O2S Monitor must be completed and the test results must be checked within the same key cycle. If the ignition key is
cycled OFF, the O2S test results will be set to the minimum or maximum limits, and all test results will be erased. The O2S test results are stored in the
ECU (SAE term: Powertrain Control Module/PCM) when the monitor is complete. The test results are static and will not change once the monitor is
complete.

The process for checking O2S test results is described in the following three basic steps:

1.

Completing the O2S Readiness Monitor.

2.

Accessing O2S Test Results.

3.

Comparing O2S Test Results to Failure Thresholds.

Required SSTs

NOTE:

Additional Diagnostic Tester Kits, Program Cards or other SSTs may be ordered by calling SPX-OTC at 1-800-933-8335.

Warranty Information

Completing O2S Readiness Monitor

1.

Clear any stored Diagnostic Trouble Codes (DTCs) using the Lexus Diagnostic Tester.

Engine Controls - O2 Sensor Monitor Threshold Values|Page 3001 > < Engine Controls - MIL ON/O2 Sensor DTC's Stored|Page 2996