7. INSPECT GENERATOR BRUSH HOLDER ASSY

a. Check the brush length.(100A Generator)

1. Using vernier calipers, measure the exposed brush length.

Standard exposed brush length: 10.5 mm (0.413 in.)
Minimum exposed brush length: 4.5 mm (0.177 in.)

If the exposed brush length is less than minimum, replace the generator brush holder.

b. Check the brush length.(130A Generator)

1. Using vernier calipers, measure the exposed brush length.

Standard exposed brush length: 10.5 mm (0.413 in.)
Minimum exposed brush length: 4.5 mm (0.177 in.)

If the exposed brush length is less than minimum, replace the generator brush holder.

8. INSPECT GENERATOR ROTOR ASSY

a. Check that bearing is not rough or worn.

If necessary, replace the generator rotor.(100A Generator) If necessary, replace the generator rotor bearing.(130A Generator)