lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Air Conditioning Unit|Page 6021 > < Air Conditioning Unit|Page 6019
Page 7
background image

3. INSTALL AIR DUCT NO.2

a. Install the air duct No. 2 with the screw.

Torque: 2.5 N.m (25 kgf.cm, 22 in.lbf) 

4. TEMPORARILY TIGHTEN AIR CONDITIONER UNIT ASSEMBLY

a. Temporarily tighten the air conditioner unit assembly with the 2 nuts.

HINT:  Make sure to hold the air conditioner unit assembly securely as its bracket installation parts may be damaged.

5. INSTALL INSTRUMENT PANEL REINFORCEMENT ASSEMBLY

a. Install the instrument panel reinforcement with the 8 bolts.

Torque: 20 N.m (204 kgf.cm, 15 ft.lbf) 

Air Conditioning Unit|Page 6021 > < Air Conditioning Unit|Page 6019