lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Evaporative Emission Control Canister|Diagrams|Page 4168 > < Evaporative Emission Control Canister|Diagrams|Page 4166
Page 3
background image

1. INSTALL CHARCOAL CANISTER ASSEMBLY

a. Connect the charcoal canister assembly with the 2 nuts.

Torque: 36 N.m (367 kgf.cm, 27 ft.lbf)

b. Install the nut.

Torque: 36 N.m (367 kgf.cm, 27 ft.lbf)

c. Align the quick connector with the pipe, then push in the quick connector until the retainer makes a "click" sound to connect the charcoal

canister fuel hose to the charcoal canister assembly.

NOTE:
-

Check that there are no scratches or foreign objects around the connected part of the quick connector and pipe before this work.

-

After connecting the charcoal canister fuel hose, confirm that it is securely connected by pulling the quick connector.

Evaporative Emission Control Canister|Diagrams|Page 4168 > < Evaporative Emission Control Canister|Diagrams|Page 4166