Page 4
background image

C. Reassemble the connector and install it into the vehicle outlet.

4. Check cable operation.

A. Plug a power outlet (cigarette lighter adapter) checker into the female side of the cable.

B. With the vehicle in ACC or ON perform a function check to make sure there is no intermittence during the function check.

C. With the male connector completely plugged into the outlet the connector should be moved a few times up and down and side to side.

D. The wire at the base of the female connector should be moved a few times up and down and side to side.

^

If there is no voltage or there are signs of intermittent operation during this moved check the 12V power outlet extension cable should be
replaced.

^

If there is voltage and it is constant during this check put a black dot on the bottom right corner of the label on the side with the fuse
information.

5. Place a black dot on the bottom right corner to show cable has been cleaned and checked. (See Figure 7.)

Refer to L-AI-0139-W, Accessories Installation Guide on Technical Information System (TIS).

6. Install cable.

Auxiliary Power Outlet|Specifications > < Electrical - Console Pwer Extension Cable Int. Inop.|Page 7753