RX 350 FWD V6-3.5L (2GR-FE) (2010)
*
If the results match the values specified above, an open circuit exists in the wire harness between terminal 1 of connector B and
terminal 1 of connector C.
3. CHECK FOR SHORT CIRCUIT
(a) If a wire in the harness is shorted to ground (Fig. 5), locate the shorted section by measuring the resistance as follows:
(b) Check the resistance to body ground.
(1) Disconnect connectors A and C and measure the resistance.
Standard Resistance (Fig. 6):
HINT
Measure the resistance while lightly shaking the wire harness vertically and horizontally.
*
If the results match the values specified above, a short circuit exists between terminal 1 of connector A and terminal 1 of connector C.
(2) Disconnect connector B and measure the resistance.
Standard Resistance (Fig. 7):
*
If the results match the values specified above, a short circuit exists between terminal 1 of connector B2 and terminal 1 of connector C.