lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6657 > < Diagram Information and Instructions|Page 6655
Page 17
background image

4. Select following menu items: DIAGNOSIS / OBD / MOBD / HV ECU / ACTIVE TEST / INSPECTION MOD3 / ON.
5. Check that the HV system warning light flashers on the multi-information display and the master warning light is illuminated in the

combination meter.

6. Start the engine by turning the ignition switch while depressing the brake pedal.

Continuity and Resistance Check

CONTINUITY AND RESISTANCE CHECK 

a. Disconnect the battery terminal or wire so there is no voltage between the check points.
b. Contact the two leads of an ohmmeter to each of the check points.

If the circuit has diodes, reverse the two leads and check again.

When contacting the negative lead to the diode positive side and the positive lead to the negative side, there should be continuity.

When contacting the two leads in reverse, there should be no continuity.

c. Use a volt/ohmmeter with high impedance (10 kohms/V minimum) for troubleshooting of the electrical circuit.

Finding A Short Circuit

FINDING A SHORT CIRCUIT

Diagram Information and Instructions|Page 6657 > < Diagram Information and Instructions|Page 6655