RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
2. Disconnect the wire harness clamp of the battery thermo sensor.
3. Remove the nut and main battery cable from the HV battery LH.
NOTE:
-
Insulate the tool with insulating tape.
-
Do not use the universal joint.
4. Remove the nut, then disconnect the EV battery plug from the HV battery.
NOTE:
-
Insulate the tool with insulating tape.
-
Do not use the universal joint.
5. Remove the HV battery LH.