RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
Knock Sensor: Testing and Inspection
INSPECTION
1. KNOCK CONTROL SENSOR
a. Using an ohmmeter, measure the resistance between the terminals.
Resistance: 120 to 280 k Ohms at 20°C (68°F)
If the resistance is not specified, replace the sensor.