Knock Sensor: Testing and Inspection

INSPECTION 

1. KNOCK CONTROL SENSOR

a. Using an ohmmeter, measure the resistance between the terminals.

Resistance: 120 to 280 k Ohms at 20°C (68°F) 

If the resistance is not specified, replace the sensor.