b. Using SST, fully tighten the oxygen sensor to the exhaust pipe sub-assembly front No.3.

SST 09224-00010

Torque: 44 N.m (449 kgf.cm, 32 ft.lbf)

c. Connect the oxygen sensor connector and clamp.

2. INSTALL OXYGEN SENSOR (for Bank 2)

a. Temporarily tighten the oxygen sensor to the exhaust pipe sub-assembly front.

NOTE:  Do not damage the oxygen sensor.

b. Using SST, fully tighten the oxygen sensor to the exhaust pipe sub-assembly front.

SST 09224-00010 

Torque: 44 N.m (449 kgf.cm, 32 ft.lbf)