RX 400h FWD V6-3.3L (3MZ-FE) Hybrid (2006)
A. Confirm correct connector color indication on the back surface of the mirror actuator (one gray and one black flat 2-pin connector).
B. Tighten the 3 screws for the actuator.
Torque: 1.5-1.96 N*m (5.30-19.99 kgf*cm,
13.28- 17.35 in*lbf)
C. For heated mirrors:
Resecure the heater terminals.
D. Connect the ECM connector to the mirror assembly.