lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

A/C - Poor Performance|Page 6859 > < A/C - Poor Performance
Page 2
background image

Components

Repair Procedure:
NOTE: Avoid using a manifold gauge set that has been used for vehicles with conventional compressor oil (ND-OIL8 or equivalent). This will cause the
compressor oil remaining in the manifold to enter the vehicle, resulting in electrical insulation performance deterioration. A manifold gauge set that has
been used 3 times or less can be reused if an appropriate one is NOT available. 

Inspect the connection of the compressor refrigerant discharge hose and the condenser.
If there is a sign of a leak, continue with this repair procedure.
1. Evacuate the refrigerant HFC-134a (R-134a).

Equipment: Robinair R--134a Refrigerant Recovery/Recycling Machine (P/N ROB342000)

A/C - Poor Performance|Page 6859 > < A/C - Poor Performance