5. Connect the battery room ventilation hose between the HV batteries LH and CTR.

NOTE:  Align the projections of the battery room ventilation hose and the rubber tube, and install the hose.

9. INSTALL BATTERY SMART UNIT

10. CHECK HIGH VOLTAGE CABLE CONNECTION

CAUTION:  Wear insulating gloves and protective glasses.

a. Check that each wire harness is being installed securely.

 

NOTE:
-

The connectors should be connected securely.

-

The nuts should be fastened securely.

-

Make sure that the 4 plastic covers are engaged securely.

11. INSTALL BATTERY COVER SUB-ASSEMBLY

CAUTION:  Wear insulating gloves.