8. CONNECT ENGINE WIRE NO.4
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Do not allow any foreign objects or water drops to enter the w/ converter inverter assembly.
a. Connect the engine wire No.4 with the connector,clamp and grommet to the w/ converter inverter assembly.
b. Connect the engine wire No.4 with the bolt to the w/converter inverter assembly.
Torque: 5.4 N.m (55 kgf.cm, 48 in.lbf)
9. CHECK HIGH VOLTAGE CABLE CONNECTION
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Do not allow any foreign objects or water drops to enter the w/ converter inverter assembly.
a. Check that each connector and terminal is firmly installed.
NOTE:
-
Make sure that the connectors are fully engaged.
-
Make sure that the bolts are fully tightened.
10. INSTALL INVERTER COVER