RX 400h FWD V6-3.3L (3MZ-FE) Hybrid (2006)
Torque: 28 N.m (286 kgf.cm, 21 ft..lbf)
c. Connect the ground cable connector.
d. Install the surge tank stay No. 2 (A) with the 2 bolts.
Torque: 20 N.m (199 kgf.cm, 14 ft.lbf)
e. Install the surge tank stay No. 1 (B) with the 2 bolts.
Torque: 20 N.m (199 kgf.cm, 14 ft.lbf)
f.
Install the engine hunger No. 1 (C) with the 2 bolts.
Torque: 20 N.m (199 kgf.cm, 14 ft.lbf)
g. Connect the ventilation hose.
h. Connect the fuel vapor feed hose (A).
i.
Connect the water by-pass hose No.3 (B).
j.
Connect the water by-pass hose No.2 (C).
k. Connect the throttle motor connector (D).