RX 450h FWD V6-3.5L (2GR-FXE) Hybrid (2010)
CAUTION:
Wear insulated gloves when performing the procedure.
(g) Connect each connector (B), (C).
5. INSTALL RADIATOR ASSEMBLY AND FAN ASSEMBLY WITH MOTOR
HINT
Refer to the procedure for Install No. 2 Radiator Assembly See: Engine, Cooling and Exhaust/Cooling System/Radiator/Service and
Repair/Radiator/Installation.
6. INSTALL SERVICE PLUG GRIP See: Hybrid Drive Systems/Battery System, Hybrid Drive/Hybrid Battery Service Switch/Service and
Repair/Service Plug Grip/Installation
7. INSTALL BATTERY SERVICE HOLE COVER See: Hybrid Drive Systems/Battery System, Hybrid Drive/Hybrid Battery Service
Switch/Service and Repair/Service Plug Grip/Installation
8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected See: Testing and
Inspection/Programming and Relearning/Repair Instruction - Initialization.
9. INSTALL REAR DECK FLOOR BOX See: Body and Frame/Interior Moulding / Trim/Headliner/Service and Repair/Removal and
Replacement/Installation
10. CHARGE WITH REFRIGERANT See: Service and Repair
11. WARM UP COMPRESSOR See: Service and Repair
12. INSPECT FOR REFRIGERANT LEAK See: Service and Repair
From 08/2009
HEATING / AIR CONDITIONING: COMPRESSOR: INSTALLATION
1. ADJUST COMPRESSOR OIL
(a) When replacing the electric inverter compressor with a new one, gradually discharge the refrigerant gas from the service valve, and drain the
following amount of oil from the new electric inverter compressor before installation.
Standard:
(Oil capacity inside the new electric inverter compressor: 120 to 135 cc (4.1 to 4.6 fl. oz.)) - (Remaining oil amount in the removed
electric inverter compressor) = (Oil amount to be removed from the new compressor when replacing)
NOTICE:
*
When checking the compressor oil level, observe the precautions on the cooler removal/installation.
*
If a new electric inverter compressor installed without removing some oil remaining in the pipes of the vehicle, the oil amount will
be too large. This prevents heat exchange in the refrigerant cycle and caused refrigerant failure.
*
If the volume of oil remaining in the removed electric inverter compressor is too small, check for oil leakage.
*
Be sure to use ND-OIL 11 or equivalent for compressor oil. If any compressor oil other than ND-OIL 11 is used, compressor motor
insulation performance may decrease, resulting in a leakage of electric power.
2. INSTALL ELECTRIC INVERTER COMPRESSOR ASSEMBLY
(a) Install the bracket with the bolt to the electric inverter compressor assembly.