(a) Wear insulated gloves. Remove the service plug grip after sliding the lever of the service plug grip.

CAUTION:
*

Keep the removed service plug grip in your pocket to prevent other technicians from accidentally reconnecting it while you are
servicing the vehicle.

*

After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or
terminals.

HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

From 08/2009

HYBRID / BATTERY CONTROL: SERVICE PLUG GRIP: REMOVAL

1. PRECAUTION

HINT
 
  See: Service Precautions.

2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected  
  See: Testing and
Inspection/Programming and Relearning/Repair Instruction - Initialization.

3. REMOVE BATTERY SERVICE HOLE COVER

(a) Disengage the 2 clips and 2 guides, and remove the battery service hole cover.

HINT
Because these are 2-piece clips, one side will remain in the bracket when they are being removed.

4. REMOVE SERVICE PLUG GRIP

CAUTION:
*

Remove the service plug grip to interrupt a high voltage circuit at the time of the check.

*

Keep the removed service plug grip in your pocket to prevent other technicians from accidentally reconnecting it while you are
servicing the vehicle.

*

All the high voltage wiring connectors are orange colored.

(a) Wear insulated gloves. Remove the service plug grip after sliding the lever of the service plug grip.