lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Charging System > < Battery Maintenance for In-Stock Vehicles|Page 2321
Page 3
background image

3.

Record the specific gravity of each cell.

TEST RESULTS:

1.

A fully charged battery will have a specific gravity reading of approximately 1.265 at 80° F.

2.

The minimum standard for this test is a specific gravity reading of 1.190. If the reading is less than 1.190, charging is necessary. Use the slow
charging procedure described in this TSIB.

3.

A difference of 0.050 or more between highest and lowest cell readings indicates a problem battery. Should you encounter this situation, attempt
one recharge using the slow charging procedure described in this TSIB. Allow the battery to stabilize at least 20 minutes after the charge cycle is
complete. Recheck the specific gravity of each cell. It the deviation in cell readings still exceeds 0.050, the battery must be replaced.

4.

After battery service is complete, reinstall the battery caps/ plugs and replace the plug labels as applicable.