Low Pressure Sensor / Switch: Description and Operation

LOW CHARGE PROTECTION SWITCH

CAUTION:  It is necessary to recover the refrigerant from the A/C system before removing the low charge protection switch.

The low charge protection switch is used to prevent A/C compressor damage in the event of a low refrigerant charge, by interrupting the ground signal
circuit between the refrigerant containment switch and ground, when the low side refrigerant pressure drops below acceptable levels. The electrical
switch contacts open when the suction pressure drops below normal levels. The Contacts close when the suction pressure rises.

The low charge protection switch is mounted on the TXV.