Constant Control Relay Module (CCRM): Customer Interest
Cooling Fan - Runs After Engine Is Shut Off

Article No. 
98-8-5

04/27/98

FAN - ENGINE COOLING FAN CONTINUES TO RUN 
AFTER ENGINE IS SHUT OFF 

LINCOLN-MERCURY: 
1995-96 CONTINENTAL

ISSUE

The cooling fan may intermittently continue to run after the engine is shut off. This may be caused by the contacts inside the Constant Control Relay
Module (CCRM) sticking closed.

ACTION

Replace the CCRM. The revised CCRM has an improved seal to resist moisture entry and reduce the possibility of the contacts sticking. Refer to the
appropriate Continental Service Manual for replacement procedures.

PART NUMBER

PART NAME    

F78Z-12B577-AB

Constant Control Relay Module 
(CCRM)

OTHER APPLICABLE ARTICLES: NONE

WARRANTY STATUS: Eligible Under The Provisions Of Bumper To Bumper Warranty Coverage

OPERATION

DESCRIPTION

TIME    

980805A

Replace Constant Control

0.3 Hr. 

Relay Module (CCRM)

DEALER CODING

CONDITION

BASIC PART NO.

CODE    

12B577

X7

     

OASIS CODES: 203000, 203100, 203200, 205000, 402000