Continental V8-4.6L DOHC VIN V (1998)
Valve Guide: Testing and Inspection
Valve - Stem Valve Guide Clearance
1. Install Valve Stem Clearance Tool on the valve stem and install Dial Indicator with Bracketry. Lower the valve until Valve Stem Clearance Tool
contacts the upper surface of the valve guide.
NOTE: Valve stem diameter must be within specifications before checking valve stem to valve guide clearance.
2. Move the Valve Stem Clearance Tool toward the Dial Indicator and zero the Dial Indicator. Move the Valve Stem Clearance Tool away from the
Dial Indicator and note the reading. The reading will be double the valve stem to valve guide clearance. Valves with oversize stems will need to be
installed if out of specification.