accumulator/drier is attached to the evaporator to accumulator/drier suction line. The outlet tube attaches to the evaporator to compressor suction line.

After entering the inlet of the suction accumulator/drier, heavier oil-laden refrigerant contacts an internally mounted dome (which serves as an umbrella)
and drips down onto the bottom of the canister.

^

A small diameter oil bleed hole, in the bottom of the vapor return tube, allows the accumulated heavier liquid refrigerant and oil mixture to
re-enter the compressor suction line at a controlled rate.

^

As the heavier mixture passes through the small diameter liquid bleed hole, it has a second change to vaporize and recirculate through the A/C
compressor without causing compressor damage due to slugging.

^

A fine mesh screened filter fits tightly around the bottom of the vapor return tube to filter out refrigerant system contaminant particles.

^

A desiccant bag is mounted inside the canister to absorb any moisture which may be in the refrigerant system.

^

A fitting located on the top of the suction accumulator/drier is used to attach the A/C cycling switch. A long-travel Schrader-type valve system
core is installed in the fitting so that the A/C cycling switch can be removed without discharging the A/C system.