background image

Expansion Block/Orifice Tube: Description and Operation

NOTE:  The A/C evaporator core orifice should be replaced whenever an A/C compressor is replaced.

The A/C evaporator core orifice has the following characteristics:

^

Color-coded orange.

^

Has an orifice diameter of 1.45 mm (0.057 inch).

^

Is located in the aft condenser to evaporator tube.

^

Has filter screens located on the inlet and outlet ends of the tube body.

^

The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.

^

O-rings on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from by-passing the A/C evaporator core orifice.

^

Adjustment or repair cannot be made to the A/C evaporator core orifice assembly. It must be replaced as a unit. This requires replacement of the
condenser to evaporator tube or installation of the Evaporator Core Orifice Replacement Kit.