Test AN5-AN7

Normal Operation

The brake fluid level switch circuit 8-GC7 (WH/RD) is open when the brake fluid level is high. When the brake fluid level is low, the switch will close
circuit 8-GC7 (WH/RD) with the ground circuit 31-GC7 (BK/BU) to signal the FEM that the brake fluid level is low. The FEM communicates the
brake fluid level status to the instrument cluster over the SCP network. The message center uses that information to display the low brake fluid
message.

Possible Causes

-

circuit 8-GC7 (WH/RD) open

-

circuit 31-GC7 (BK/BU) open

-

brake fluid switch

-

instrument cluster

Tests AO

PINPOINT TEST AO: THE INDICATOR DOES NOT OPERATE CORRECTLY - DOOR AJAR DISPLAY 