8. Rotate the manual control lever forward until the travel stops. Then rotate the manual control lever back 2 detents to the (D) position.

9. NOTE:  When installing the selector lever cable, make sure that the selector lever cable locking tabs are locked in place and the selector lever

cable end is snapped onto the ball stud. Press the selector lever cable into the bracket and listen for the selector lever cable to click in place. Pull
back on the selector lever cable to make sure that it is locked into the bracket. Also make sure that the selector lever cable end is correctly installed
onto the ball stud. Pull back on the selector lever cable end to make sure that the selector lever cable end is correctly installed.

Connect the selector lever cable to the selector lever cable bracket. Connect the selector lever cable to the manual control lever.
1

Install the new selector lever cable retainer.

2

Connect the selector lever cable to the selector lever cable bracket and rotate the lock downward to lock the adjuster.

10. Connect the electrical connector to the selector lever cable bracket.