background image

5. Install the manual control valve detent lever spring and loosely install the bolt.

6. Tighten the bolts in the sequence shown.

^

Tighten to 10 Nm (89 lb-in).

7. Inspect the molded lead frame for damage.

^

Using the special tool, check all molded lead frame solenoid connections. The gauge should fit tightly and not fall out after being inserted.

^

If the special tool easily passes through any molded lead frame connector pins or does not feel like it makes a good contact, install a new
molded lead frame.

Removal and Replacement|Page 4884 > < Removal and Replacement|Page 4882