Mark LT 2WD V8-5.4L (2008)
5. Install the manual control valve detent lever spring and loosely install the bolt.
6. Tighten the bolts in the sequence shown.
^
Tighten to 10 Nm (89 lb-in).
7. Inspect the molded lead frame for damage.
^
Using the special tool, check all molded lead frame solenoid connections. The gauge should fit tightly and not fall out after being inserted.
^
If the special tool easily passes through any molded lead frame connector pins or does not feel like it makes a good contact, install a new
molded lead frame.