lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9088 > < Initial Inspection and Diagnostic Overview|Page 9086
Page 5
background image

J7 Continued

Normal Operation

Circuit 511 (LG) supplies voltage to the multifunction switch and the high mounted stoplamp when the brake pedal is applied. The multifunction
switch internally routes the voltage (when in the NEUTRAL position) to circuits 9 (LG/OG) (LH stoplamp) and 5 (OG/LB) (RH stoplamp). Circuits 9
(LG/OG) and 5 (OG/LB) are routed through the central junction box (CJB) and then to the LH and RH stoplamps, accordingly.

Possible Causes

-

Circuit 5 (OG/LB) open

-

Circuit 9 (LG/OG) open

-

Circuit 57 (BK) open

-

Circuit 511 (LG) open

-

Multifunction switch

-

CJB

Test K: The Stoplamps Are On Continuously

PINPOINT TEST K: THE STOPLAMPS ARE ON CONTINUOUSLY

K1