C4-C8

Normal Operation

For vehicles equipped with RKE, the vehicle security module sends an interior lamps ON request to the instrument cluster through UART based
protocol (UBP) network circuit 1906 (PK) whenever a door has been opened, the unlock button has been pressed on the remote transmitter, or when
an unlock request has been entered with the keyless keypad (if equipped). The interior lamps can also be turned ON or OFF with the dimmer control
switch, which provides a ground signal to the instrument cluster through circuit 402 (OG/LG) when the dimmer control switch is turned ON. When the
instrument cluster receives the interior lamps ON request from the vehicle security module or the dimmer control switch, the instrument cluster
energizes circuit 53 (BK/LB), which provides power to the interior lamps. The interior lamps are grounded through circuit 57 (BK). The interior
lamps remain illuminated until the instrument cluster removes voltage from circuit 53 (BK/LB).

For non-RKE vehicles, the instrument cluster energizes circuit 53 (BK/LB) when a door has been opened, which provides power to the interior lamps.
The interior lamps can also be turned ON or OFF with the dimmer control switch. The interior lamps are grounded through circuit 57 (BK), and will
remain illuminated until the instrument cluster removes voltage from circuit 53 (BK/LB).

Possible Causes

-

Circuit 53 (BK/LB) short to voltage