lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Recall - Catalyst Inspection and/or Replacement|Page 3944 > < Recall - Catalyst Inspection and/or Replacement|Page 3942
Page 8
background image

1.

Insert converter hanger rod into hanger brackets.

2.

Connect HEGO sensor.

3.

Position converter to inlet pipes and install new retaining bolts. Do not tighten bolts.

4.

Position muffler inlet flange to converter outlet flange and install retaining nuts. Do not tighten nuts.

5.

Align exhaust system, refer to illustration.

6.

With exhaust system aligned:
a.

Tighten converter to exhaust manifold nuts to 22-32 N-m (16-24 Lb.Ft.).

b.

Tighten muffler inlet pipe to converter outlet flange retaining nuts to 27-40 N-m (20-29 Lb.Ft.). Refer to illustration.

c.

Install air tube and check valve.

7.

Check system for leaks and lower vehicle.

AUTHORIZED MODIFICATIONS DECAL

Recall - Catalyst Inspection and/or Replacement|Page 3944 > < Recall - Catalyst Inspection and/or Replacement|Page 3942