NOTE: Make sure ignition wire clips are fully seated to ignition coils.

30. Connect ignition wires to ignition coils

31. Connect ignition wires as numbered to proper cylinder spark plugs.
32. Install ignition wire rubber separators into valve cover slots and install ignition wire covers. Install eight retaining nuts and tighten to 2-4  Nm

(18-35 lb in).

33. Position engine air cleaner outlet tube bracket on RH valve cover and install two retaining nuts. Tighten to 8-12  Nm (71-106 lb in).
34. Install drive belt.
35. Connect fuel tubes.
36. Install air cleaner outlet tube, engine intake air resonator and engine appearance cover.
37. Install windshield wiper module assembly.

CAUTION: Use extreme care to keep coolant mixture off of drive belt and pulleys. If needed, remove drive belt and rinse with clear water. Clean
pulleys and install drive belt. Drive belt squeal and early drive belt fatigue will occur otherwise.