Page 21
background image

GO to I2.

No

VERIFY the SJB fuse 5 (10A) is OK. If OK, GO to I4. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the short circuit.

-------------------------------------------------
I2 CHECK THE SJB GROUND CIRCUITS FOR AN OPEN

-

Ignition OFF.

-

Disconnect: SJB C2280d.

-

Measure the resistance between the SJB C2280d-8, circuit GD133 (BK), harness side and ground; between the SJB C2280d-12, circuit GD133
(BK), harness side and ground.

-

Are the resistances less than 5 ohms?

Yes

GO to I3.

No

REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
I3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SJB AND THE DLC FOR AN OPEN

-

Disconnect: SJB C2280b.

-

Measure the resistance between the SJB C2280b-37, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG),
harness side.

-

Measure the resistance between the SJB C2280b-38, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG),
harness side.

-

Are the resistances less than 5 ohms?

Yes

GO to I4.

Initial Inspection and Diagnostic Overview|Page 2699 > < Initial Inspection and Diagnostic Overview|Page 2697