Page 44
background image

No

VERIFY the Smart Junction Box (SJB) fuse 31 (10A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams to identify the
possible causes of the short circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S2 CHECK THE HCM-2 GROUND CIRCUIT FOR AN OPEN

-

Measure the resistance between the inline HCM-2 C913-E, circuit GD133 (BK), harness (female) side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to S3.

No

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S3 CHECK THE MS-CAN CIRCUITS BETWEEN THE HCM-2 AND THE DLC FOR AN OPEN

-

Measure the resistance between the inline HCM-2 C913-C, circuit VDB06 (GY/OG), harness (female) side and the DLC C251-3, circuit VDB06
(GY/OG), harness side.

-

Measure the resistance between the inline HCM-2 C913-F, circuit VDB07 (VT/OG), harness (female) side and the DLC C251-11, circuit VDB07
(VT/OG), harness side.

-

Are the resistances less than 5 ohms?

Yes

GO to S4.

No

REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the scan tool.