lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2723 > < Initial Inspection and Diagnostic Overview|Page 2721
Page 45
background image

-------------------------------------------------
S4 CHECK FOR CORRECT HCM-2 OPERATION

-

Disconnect the HCM-2 connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the HCM-2 connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new HCM-2. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test T: The Remote Function Actuator (RFA) Module Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test T: The Remote Function Actuator (RFA) Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

The Remote Function Actuator (RFA) module communicates with the scan tool through the High Speed Controller Area Network (HS-CAN). Circuits
VDB04 (WH/BU) (HS-CAN +) and VDB05 (WH) (HS-CAN -) provide the HS-CAN connection to the RFA module and circuits VDB06 (GY/OG)
(MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the Medium Speed Controller Area Network (MS-CAN) connection to the RFA module.
Voltage for the RFA module is provided by circuits SBP12 (GN/RD) and SBP27 (BU/RD). Circuits GD114 (BK/BU) and GD116 (BK/VT) provides
ground.

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

RFA module

PINPOINT TEST T: THE RFA MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
T1 CHECK THE RFA MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: RFA Module C2153c (Blue Hardshell).

-

Ignition ON.

-

Measure the voltage between the RFA module C2153c-1, circuit SBP27 (BU/RD), harness side and ground; and between the RFA module
C2153c-2, circuit SBP12 (GN/RD), harness side and ground.

Initial Inspection and Diagnostic Overview|Page 2723 > < Initial Inspection and Diagnostic Overview|Page 2721