Removal and Installation

1. Remove the fuel tank.

2. Disconnect the Fuel Tank Pressure (FTP) sensor electrical connector.

3. Disconnect the fuel vapor tube assembly-to-Fuel Pump (FP) module quick connect coupling.

4. Release the retainer clips and remove the fuel vapor tube assembly.

5. To install, reverse the removal procedure.

-

Carry out the Evaporative Emission System Leak Test. For additional information, refer to Evaporative Emission System Leak Test  See: