lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2989 > < Initial Inspection and Diagnostic Overview|Page 2987
Page 92
background image

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
W72 CHECK FOR CORRECT SDARS MODULE OPERATION

 

-

Disconnect the SDARS module connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the SDARS module connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SDARS module. REFER to Accessories and Optional Equipment. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
W73 CHECK FOR CORRECT PRB MODULE OPERATION

 

-

Disconnect all the PRB module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the PRB module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new PRB module. REFER to Auxiliary Step / Running Board. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
W74 CHECK FOR CORRECT PAM OPERATION

 

-

Disconnect all the PAM connector(s).

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the PAM connector(s) and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Initial Inspection and Diagnostic Overview|Page 2989 > < Initial Inspection and Diagnostic Overview|Page 2987