Tighten to 25 Nm (18 lb-ft).

8. Disconnect the generator electrical connector.

9. Position the generator B+ protective cover aside, remove and discard the nut, then position the generator B+ terminal aside.

-

Install a new B+ terminal nut and tighten to 17 Nm (150 lb-in).

10. Remove the generator.

11. To install, reverse the removal procedure.