lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 2571
Page 1
background image

Refrigerant: Service and Repair

SPECIAL SERVICE TOOL(S)

CAUTION:  The A/C refrigerant of all vehicles must be identified and analyzed prior to refrigerant charging. Failure to do so can contaminate the shop
bulk refrigerant and other vehicles.  See: Heating and Air Conditioning/Service and Repair/Identifying Refrigerants

1. Connect the R-134a A/C Refrigerant Center to the low and high-pressure service gauge port valves.
2. Recover the refrigerant from the system following the operating instructions provided by the equipment manufacturer.
3. Once the service center has recovered the vehicle A/C system refrigerant, close the service center inlet valve (if so equipped). Then switch off the

power supply.

4. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the pressure

does not rise, disconnect the recovery station hose(s).

5. If the system pressure rises, repeat steps 2 through 5 until the vacuum level remains stable for two minutes.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 2571