lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Auxiliary Climate Control|Page 2523 > < Auxiliary Climate Control|Page 2521
Page 20
background image

6. Connect the heater water outlet line to the heater water outlet line.

1

Connect the fitting. 

2

Loosely install the nut.

7. Tighten the three peanut fittings.

8. Install the line brackets.

1

Position the bracket.

2

Install the nut.
^

Snap the line securely into the bracket.

CAUTION:
^

Verify that clearance exists between the frame and the lines to prevent component damage.

^

Overtightening of the nut will cause the stud to break away from the floorpan.

NOTE:  The bracket must be positioned equally between the white location marks on the line.

9. Connect the heater water outlet line to the engine heater outlet hose coupling.

^

Lubricate the coolant hoses with MERPOL(R) meeting Ford specification ESE-M99B144-B or plain water only, if needed.

Auxiliary Climate Control|Page 2523 > < Auxiliary Climate Control|Page 2521