6. Remove the thermostatic expansion valve fitting bolt.

-

Discard the O-ring seals.

7. Remove the bolts and the thermostatic expansion valve.

-

Discard the O-ring seals.

8. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

9. Evacuate, leak test and charge the refrigerant system.

Auxiliary Climate Control

THERMOSTATIC EXPANSION VALVE

Removal and Installation

1. Recover the refrigerant.
2. Remove the RH quarter trim panel.

3. Disconnect the fittings and remove the thermostatic expansion valve.

-

Discard the O-ring seals.

4. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

5. Evacuate, leak test and charge the refrigerant system.