Accumulator HVAC: Service and Repair

REMOVAL 

1. Disconnect the battery ground cable.
2. Recover the refrigerant.

3. Disconnect the A/C cycling switch electrical connector.

4. Disconnect the manifold and tube fitting.

CAUTION:  Use a back-up wrench to prevent damage to the tubes.

5. Remove the suction accumulator bracket clamp bolt.

6. Disconnect the suction accumulator/drier spring lock coupling from the A/C evaporator core.

Accumulator HVAC|Specifications|Page 9002 > < Accumulator HVAC|Specifications|Page 9000