Navigator 4WD V8-5.4L SOHC VIN L (1998)
7. CAUTION: Make sure the CBV is in the solvent tank before switching on the solvent pump. Also make sure the CBV fitting is pointing
downward so the solvent does not spray up out of the tank.
Place the CBV into the solvent tank.
8. CAUTION: The solvent pressure must be at least 344.75 kPa (50 psi) (minimum) to overcome the valve inside the CBV and let the solvent pass
through it. Do not, however, exceed 620.55 kPa (90 psi) (maximum) solvent pressure.
Regulate the solvent pressure as specified. Switch on the solvent pump allowing the solvent to circulate through the CBV for 5 minutes. During
this time, cycle the solvent pump on and off to help dislodge contaminants.
9. Disconnect the cleaner pressure line from the case converter-out fitting. Remove the 0.5-inch washer.
10. Using 344.75-620.55 kPa (50-90 psi) of regulated compressed air, blow through the CBV until all solvent is removed.
11. Remove the plug from the CBV converter-out-to-cooler inlet.
ASSEMBLY