2. Remove the nut and disconnect the A/C fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

3. Remove the nut and disconnect the A/C fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

4. Remove the 2 bolts and the thermostatic expansion valve (TXV) manifold and tube assembly.

-

To install, tighten to 8 Nm (71 lb-in).

5. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

6. Evacuate, leak test and charge the refrigerant system.