J7

Normal Operation

The stoplamp switch is supplied voltage from the central junction box (CJB) fuse 2 (20A) through circuit 10 (LG/RD). When the brake pedal is
applied, the stoplamp switch routes voltage to the high mounted stoplamp and the multifunction switch through circuit 511 (LG). The multifunction
switch then routes the voltage to the CJB through circuit 9 (LG/OG) and circuit 5 (OG/LB). The CJB then routes the voltage to the LH stoplamp and
RH stoplamp through circuit 9 (LG/OG) and circuit 5 (OG/LB) respectively.

Possible Causes

-

Circuit 5 (OG/LB) short to voltage

-

Circuit 9 (LG/OG) short to voltage

-

Circuit 52 (YE) short to voltage

-

Circuit 64 (DG) short to voltage

-

Circuit 511 (LG) short to voltage

-

Stoplamp switch

-

Multifunction switch

-

Trailer tow electric brake controller

-

CJB