lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Vacuum Delay Valve, EVAP > < Liquid Vapor Separator, Evaporative System|Description and Operation
Page 1
background image

Thermal Vacuum Valve - EVAP: Description and Operation

Fig. 18 Ported vacuum switches--PVS

These switches, Fig. 18, control vacuum to emission components during engine warm-up. The 2-port and 4-port types open when coolant
temperature reaches a predetermined value. The 3-port type switches vacuum from the center to the top or bottom ports. Electrical switches can be
opened or closed until the PVS is fully cycled. All PVS units are temperature-activated and have a specific opening and closing temperature. 

Vacuum Delay Valve, EVAP > < Liquid Vapor Separator, Evaporative System|Description and Operation